Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 147
Filtrar
1.
Arq. bras. oftalmol ; 87(2): e2021, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527839

RESUMO

ABSTRACT Purpose: Diabetes mellitus is a leading cause of impaired vision. The objective of this study was to evaluate the feasibility of use of portable retinograph and remote analysis of images along with a virtual questionnaire for screening for diabetic retinopathy in basic health units in the city of Ribeirão Preto/SP during the Covid-19 pandemic. Methods: Standard Covid-19 protocol was followed during the screening. Blood pressure and capillary blood glucose were measured. Demographic and social data were collected through a standardized online questionnaire via smartphone. After pupillary dilation, fundal images were obtained with portable retinographs by trained ophthalmology residents. Two standardized 45° images were acquired: one posterior segment and another nasal to the optic nerve. Diabetic retinopathy was classified according to the Early Treatment Diabetic Retinopathy Study. Results: A total of 350 patients (64% female; 45% aged 55-70 years; 55% Caucasian) were evaluated. For 40.5% of patients, the campaign was the first opportunity for retinal evaluation; 47.56% had diabetes mellitus for >10 years. On repeat analysis of images stored in a cloud-based repository by retinal specialist, a 7.8% difference was observed in the Early Treatment Diabetic Retinopathy Study diabetic retinopathy classification, compared to the screening findings. Mild diabetic retinopathy was observed in 12.23%, moderate diabetic retinopathy in 6.31%, and proliferative diabetic retinopathy in 2.58% patients. Macular edema was present in 4.58% patients. Diabetic retinopathy was not detected in 72.78% patients. Conclusion: Use of portable retinographs together with telemedicine can provide efficient alternative to traditional methods for screening and diagnosis of diabetic retinopathy.


RESUMO Objetivo: A diabetes mellitus é considerada uma epidemia global e causa de baixa visual em países em desenvolvimento. Este estudo foi realizado com o objetivo de avaliar a viabilidade do retinógrafo portátil e análise remota de imagens associada a questionário virtual para o rastreio de retinopatia diabética em Unidades Básicas de Saúde da cidade de Ribeirão Preto/SP durante a pandemia de Covid-19. Métodos: Trezentos e sessenta pacientes compareceram a campanha. O acolhimento foi realizado na Unidade Básica de Saúde pela equipe de enfermagem, respeitando medidas de prevenção do Covid-19 Os realizou-se aferição da pressão arterial e glicemia capilar seguida de dilatação. Dados demográficos e sociais foram coletados através de questionário on-line padronizado via smartphone e realizou-se a triagem da retinopatia diabética através da obtenção de imagens com retinógrafos portáteis realizados por residentes de oftalmologia previamente treinados, com a aquisição de 2 imagens padronizadas de 45º: uma do segmento posterior e outra nasal ao nervo óptico. Resultados: Trezentos e sessenta pacientes foram atendidos durante a campanha. Dez pacientes (1,02%) foram excluídos devido à opacidade de meios e impossibilidade de obtenção de imagens de fundo de olho. Foram avaliados 350 pacientes, 64% do sexo feminino, 45% entre 55 e 70 anos e 55% brancos. A Campanha foi a primeira avaliação de retina para 40,5% dos pacientes e 47,56% apresentavam diabetes mellitus há mais de 10 anos. Na análise comparativa da classificação da retinopatia diabética segundo Early Treatment Diabetic Retinopathy Study (triagem X Nuvem) observou-se uma diferença de 7,8% nos resultados. Retinopatia diabética leve foi observada em 12,23%, moderada em 6,31%, proliferativa em 2,58%; edema macular presente em 4,58% e ausência de retinopatia diabética em 72,78% dos pacientes. Conclusão: A utilização de retinógrafos portáteis juntamente a telemedicina, para o rastreamento da retinopatia diabética pode ser considerada uma alternativa eficiente para triagem e diagnóstico da retinopatia diabética dentro ou fora do cenário pandêmico, auxiliando na prevenção de perda visual pelo diabetes.

2.
Rev Port Cardiol ; 42(1): 53-59, 2023 01.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36116990

RESUMO

INTRODUCTION: In patients with cryptogenic stroke, one of the most frequently found abnormalities is patent foramen ovale (PFO). Percutaneous 'deviceless' systems based on surgical suture-mediated PFO closure have recently been introduced and show a favorable efficacy and safety profile with clear advantages. OBJECTIVES: To present procedural details of the technique and baseline characteristics of patients who underwent the procedure in our center. METHODS: A single-center prospective observational registry was established between February 2020 and February 2021, to assess the safety, efficacy and possible advantages of a novel percutaneous PFO closure system (NobleStitch® EL). Patient and PFO characteristics as well as technical features were collected for analysis. RESULTS: Twenty-three patients were considered suitable for this technique after transesophageal echocardiography. Their mean age was 51 years and 69.5% were women. Most patients (91.3%) had a history of cryptogenic stroke. PFO closure with the NobleStitch® system was successfully performed in all patients. All procedures were performed under local anesthesia and fluoroscopic monitoring. The mean duration of the procedure was 52 min and median contrast dose used was 187 ml. Median radiation dose absorbed per patient was 61.5 Gy cm2. All patients were discharged asymptomatic 24 hours after the procedure with no peri- or postprocedural complications recorded. CONCLUSION: Suture-mediated PFO closure represents a valid and safe alternative to traditional umbrella-like devices, and is feasible in the majority of PFO anatomies. Follow-up information, results of larger series and clinical trials may possibly validate this technique as the first choice for PFO closure.


Assuntos
Forame Oval Patente , AVC Isquêmico , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Resultado do Tratamento , Portugal , Cateterismo Cardíaco/métodos , AVC Isquêmico/complicações , Suturas/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversos
4.
Braz. dent. sci ; 26(2): 1-9, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1437119

RESUMO

Objective: to compare the quality of obturation, instrumentation time and post-operative pain after pulpectomy in primary molars using manual K-files, Kedo-S and Kedo-S Square rotary file systems. Material and Methods: a double blinded randomized control trial was conducted in 45 children, who were indicated for pulpectomy in any one of the primary mandibular molars. The canal preparation was done using either hand K-files, Kedo-S files, or Kedo-S Square files based on the groups assigned. The time taken for instrumentation was recorded using a stopwatch. The quality of obturation was evaluated using post-operative radiograph and post-operative pain was assessed with modified Wong-Baker Faces Pain scale. Results: instrumentation time was minimum in rotary Kedo-S Square files (53.23 ± 9.60 seconds) followed by Kedo-S files (82.70 ± 11.86 seconds). The preparation time was maximum with manual K-files (121.43 ± 20.18 seconds). Kedo-S square files provided a higher number of optimally filled canals (66.4%). All the three instrumentations equally showed the tendency to produce voids in the obturation. Rotary files Kedo-S Square followed by Kedo-S showed less post-operative pain compared to K-files. Conclusion: the use of pediatric rotary instruments for canal preparation during pulpectomy will result in better quality of obturation in reduced time with least post-operative pain (AU)


Objetivo: comparar a qualidade de obturação, tempo de instrumentação e dor pós-operatória após pulpectomia em molares decíduos usando limas manuais K, limas rotatórias Kedo-S e limas rotatórias Kedo-S Square. Material e Métodos: um estudo clínico randomizado duplo-cego foi conduzido com 45 crianças que foram submetidas à pulpectomia de algum molar decíduo indicado. A preparação do canal foi feita usando limas manuais K, ou limas Kedo-S, ou ainda Limas Kedo-S Square, com base nos grupos que foram selecionados. O tempo para a instrumentação foi registrado com um cronômetro. A qualidade de obturação foi avaliada por meio de uma radiografia após o procedimento e a dor pós-operatória foi avaliada com a escala de dor Wong-Baker Faces modificada. Resultados: o tempo de instrumentação foi mínimo para as limas rotatórias Kedo-S Square (53,23 ± 9,60 segundos) seguido pelas limas Kedo-S (82,70 ± 11,86 segundos). O tempo de preparação foi maior com as limas manuais K (121,43 ± 20,18 segundos). As limas Kedo-S Square promoveram um maior número de canais otimamente obturados (66,4%). Todas as três instrumentações mostraram igualmente a tendência em seproduzir vazios na obturação. As limas rotatórias Kedo-S Square seguidas pelas limas Kedo-S produziram menos dor pós-operatória comparadas às limas manuais K. Conclusão: o uso de instrumentos rotatórios pediátricos para a preparação do canal durante a pulpectomia resultará em melhor qualidade de obturação em tempo reduzido e com menos dor pós-operatória. (AU)


Assuntos
Humanos , Criança , Dor Pós-Operatória , Pulpectomia , Obturação do Canal Radicular , Criança
5.
Arq. bras. oftalmol ; 85(5): 443-449, Sept.-Oct. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403439

RESUMO

ABSTRACT Purpose: To evaluate the vision quality by measuring the objective light scatter index and objective optical quality parameters (Strehl Ratio and Modulation Transfer Function) in patients with emmetropia and ametropia. Methods: This prospective, cross-sectional study included 408 eyes. The ametropic group comprised of eyes with best-corrected visual acuity of 0.0 logMAR or better and present at least a refractive error of ≥0.25 D. Patients underwent slit lamp examination, visual acuity, refraction, and vision quality using the HD Analyzer. Results: The mean objective light scatter indices were 0.62 ± 0.63, 0.77 ± 0.70, 0.74 ± 0.30, 0.93 ± 0.55, and 0.85 ± 0.61, and mean Strehl Ratio and Modulation Transfer Function scores were 38.17 ± 10.4, 37.37 ± 10.06, 29.84 ± 9.71, 33.2 ± 12.11, and 33.13 ± 10.09 in emmetropes, myopia, hyperopia, spherical equivalent of ≥0, and spherical equivalent of <0, respectively. Differences in all variables were significant between emmetropic and corrected hyperopic and between spherical equivalent of ≥0, and spherical equivalent of <0 eyes (p<0.05). Conclusion: In spectacle-corrected conditions (with trial frames), emmetropic and simple myopic eyes had significantly better vision quality compared to hyperopic and astigmatic eyes. The clinical significance of these results should be investigated in further studies.


RESUMO Objetivo: Avaliar a qualidade óptica medindo o índice de dispersão objetiva de luz e os parâmetros de qualidade óptica objetiva (Razão de Strehl e Função de Transferência de Modulação) em indivíduos com emetropia e ametropia. Métodos: Estudo prospectivo, transversal, incluindo 408 olhos. O grupo ametrópico era de olhos com melhor acuidade visual corrigida de 0,0 logMAR ou melhor e apresentando, pelo menos, um erro refrativo de 0,25 D ou mais. Os pacientes foram submetidos a exame com lâmpada de fenda, acuidade visual, refração e qualidade óptica com o HD Analyzer. Resultados: O índice de dispersão objetiva de luz médio foi de 0,62 ± 0,63, 0,77 ± 0,70, 0,74 ± 0,30, 0,93 ± 0,55, 0,85 ± 0,61 e a média da Razão de Strehl e de Função de Transferência de Modulação foram 38,17 ± 10,4, 37,37 ± 10,06, 29,84 ± 9,71, 33,2 ± 12,11 e 33,13 ± 10,09 em olhos emetrópicos, míopes, hipermétropes, equivalente esférico ≥0 e equivalente esférico <0 respectivamente. Foram encontradas diferenças significativas em todas as variáveis entre olhos emetrópicos e com hipermetropia corrigida, equivalente esférico ≥ 0 e equivalente esférico <0 (p<0,05). Conclusão: Em condições com lentes corrigidas (com armações de prova), os olhos emetrópicos e com miopia simples apresentaram qualidade óptica significativamente melhor em comparação com os olhos hipermétropes e astigmáticos. O significado clínico destes resultados deve ser estudado posteriormente.

6.
Arq. bras. oftalmol ; 85(3): 229-234, May-June 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383804

RESUMO

ABSTRACT Purpose: To examine changes in the eyes after cold compress application at the early stage. Method: A total of 62 eyes from 62 healthy adult participants were included in this cross-sectional and comparative study. The subfoveal choroidal thickness and retinal nerve fiber thickness were measured by spectral-domain ocular coherence tomography. The central corneal thickness, anterior segment volume and depth, iridocorneal angle, and pupil diameter were measured by means of the Scheimpflug anterior segment imaging method. The measurements were repeated after 10 min of cold compress application, which was applied using special packs. The procedures were then repeated with non-cold packages to exclude the effect of pressure. Results: The average age of the participants was 30.74 ± 5.82 years. There was no significant change in the central corneal thickness after cold compress application, and there was a significant decrease in the anterior segment volume (p<0.001), anterior segment depth (p<0.001), and pupil diameter. Moreover, the iridocorneal angle increased (p=0.002). The subfoveal choroidal thickness decreased after the application of cold compress (p<0.001). The overall disk thickness (p=0.034) and superior nasal scale (p=0.007) significantly decreased after the cold compress was administered during the evaluation of optic nerve fiber thickness. In contrast to that with the cold application, the subfoveal choroidal thickness and optic nerve fiber thickness did not change after the non-cold compress application (p>0.05). Conclusion: Cold compress application may thus cause some physiological changes in the eyes, which necessitates the examination of its usage and effects.


RESUMO Objetivos: Examinar as mudanças nos olhos após a aplicação com compressa fria. Método: Sessenta e dois olhos de 62 adultos saudáveis foram incluídos neste estudo transversal e comparativo. A espessura da coróide subfoveal e a espessura da fibra nervosa retiniana foram mensuradas por tomografia de coerência óptica de domínio espectral (OCT). A espessura central da córnea, o volume e a profundidade do segmento anterior, o ângulo iridocorneano e o diâmetro da pupila foram mensurados por meio do método de imagem do segmento anterior de Scheimpflug. As medições foram repetidas após 10 minutos de aplicação de compressas frias, aplicadas com embalagens especiais. Os procedimentos foram repetidos com embalagens não frias para excluir o efeito da pressão. Resultados: A média de idade dos participantes foi de 30,74 ± 5,82 anos. Embora não tenha havido alteração significativa na espessura central da córnea após a aplicação da compressa fria, houve diminuição significativa no volume do segmento anterior (p<0,001), na profundidade do segmento anterior (p<0,001) e no diâmetro da pupila. Além disso, o ângulo iridocorneano aumentou (p=0,002). A espessura da coróide subfoveal diminuiu após a aplicação da compressa fria (p<0,001). A espessura total do disco (p=0,034) e a escala nasal superior (p=0,007) diminuíram significativamente após a administração da compressa fria durante a avaliação da espessura da fibra do nervo óptico. Ao contrário da aplicação com compressa fria, a espessura da coróide subfoveal e a espessura da fibra do nervo óptico não mudaram após a aplicação da compressa não fria (p>0,05). Conclusão: A aplicação de compressa fria pode causar algumas alterações fisiológicas nos olhos e o seu uso e efeitos devem ser observados.

7.
Rio de Janeiro; s.n; 2022. 129 p.
Tese em Português | BBO - Odontologia | ID: biblio-1415074

RESUMO

Objetivou-se elaborar um e-book aos cirurgiões-dentistas sobre as opções de sistema de instrumentação endodôntica para dentes decíduos e comparar os resultados biomecânicos de diferentes sistemas e seu tempo de preparo em protótipos de dentes decíduos por meio de uma análise em micro-CT. Para isso, foram realizados dois estudos. No primeiro, realizou-se uma busca bibliográfica em seis bases de dados por estudos laboratoriais e clínicos sobre protocolos de pulpectomia utilizando pelo menos uma técnica de instrumentação. Dados a respeito das características, cinemática, benefícios e orientações à cerca da utilização de acordo com as instruções dos fabricantes foram extraídos para elaboração do conteúdo teórico e diagramação do layout do e-book, confeccionado no programa Canva. Após finalizado, o mesmo foi avaliado por três pós-graduandos da Disciplina de Odontopediatria da FOUFRJ e as sugestões foram incorporadas. Elaborou-se o material intitulado ''Guia ilustrado de instrumentação endodôntica para dentes decíduos'' contendo 43 páginas, abordando 13 sistemas de instrumentação, com sequências ilustradas de protocolos para utilização. Para o segundo estudo foram utilizados 60 protótipos padronizados de segundos molares decíduos inferiores confeccionados em polímero transparente para avaliar os resultados biomecânicos da instrumentação com diferentes sistemas de limas. Foram utilizados os sistemas manual k-file e mecanizados ProTaper Nextâ (PTN), XP- Endoâ Shaper (XPS), XP- Endoâ Finisher (XPF), XP­Clean (XPC) e Sequence Baby file (SBF) (n= 10/cada). A instrumentação foi realizada por um único operador treinado e o tempo de utilização de cada sistema foi cronometrado. Realizouse a irrigação com um total de 16mL de soro fisiológico à 0,9% para cada canal instrumentado, associada a aspiração simultânea. Os protótipos foram escaneados antes e após da instrumentação através do micro-CT. A reconstrução foi padronizada os conjuntos de imagens iniciais e instrumentados foram registrados entre si. Alterações no volume do canal radicular, área não instrumentada, debris acumulados, volume de dentina removido e transporte do canal foram quantificados. Os dados foram tabulados no programa JAMOVI versão 1.6 e analisados através do teste Shapiro-Wilk para verificar a distribuição dos dados. Para distribuição normal foram realizados testes paramétricos e para aqueles que não seguiram a normalidade, testes não paramétricos foram utilizados, todos com um nível de significância de 5% (p<0,05). A instrumentação com sistemas mecanizados resultou em menos tempo de instrumentação (p< 0,001) do que com a k-file. A porcentagem de áreas não instrumentadas foi semelhante para todos os sistemas. O acúmulo de debris foi maior para K-file e XPS ao longo de todo o canal (p<0,05). Todos os grupos apresentaram aumento do volume do canal radicular após a instrumentação (p= 0,003) com valores mais elevados na lima K-file (p<0,05). A análise 3D revelou maior transporte da lima K-file. SBF e K-file apresentaram, respectivamente, o menor (0,01 ± 0,01 e 0,03 ± 0,04) e o maior (0,04 ± 0,05 e 0,32 ± 0,94) valor de transporte do canal nos protótipos. Diante das metodologias utilizadas, conclui-se que um material relevante e prático ficará disponível nas plataformas digitais da Disciplina de Odontopediatria da UFRJ, para livre acesso e ampla divulgação aos cirurgiões-dentistas. Além disso, com relação aos resultados de instrumentação mecânica, o SBF e o XPC resultaram em uma abordagem mais conservadora. A instrumentação mecânica pode levar à algum grau de transporte do canal e deixar partes das paredes do canal infectadas sem preparo mecânico. (AU)


The objective was to elaborate an e-book to dentists about the options of endodontic instrumentation system for primary teeth and to compare the biomechanical outcomes of the different systems and their instrumentation time in prototypes of primary teeth through micro-CT analysis. To this end, two studies were carried out. In developing the first, a bibliographic search was carried out in six databases. Laboratory and clinical studies with a pulpectomy protocol using at least one instrumentation technique were included. Data about features, kinematics, benefits, and guidelines on use according to the manufacturer's instructions were extracted to prepare the theoretical content and layout diagramming of the e-book using Canva software. Afterwards, it was evaluated by 3 postgraduate students of the Pediatric Dentistry Discipline-FOUFRJ and the suggestions for changes were incorporated. The product entitled 'Guia ilustrado de instrumentação endodôntica para dentes decíduos' contains 43 pages covering 13 instrumentation systems and illustrated sequence of protocols use for each. The second consists of 60 standardized prototype teeth of mandibular second primary molars made with transparent polymer to evaluate the outcomes of biomechanical instrumentation of different systems. Manual k-file, ProTaper Nextâ (PTN), XP-Endoâ Shaper (XPS), XP-Endoâ Finisher (XPF), XP ­ Clean (XPC) and Sequence Baby file (SBF) (n= 10/each) were used. The specimen instrumentation was performed by a single trained and the time spend was recorded. Irrigation was performed with a total of 16mL of 0.9% saline solution for each instrumented canal and simultaneous aspiration. The prototypes were scanned before and after the instrumentation using micro-CT. In addition, the reconstruction was standardized and initial and instrumented image sets were registered with each other. Next, changes in root canal volume, noninstrumented areas, accumulated debris, removed dentin volume and canal transportation were quantified. Data were tabulated in the JAMOVI program version 1.6 and analyzed using the Shapiro-Wilk test to verify the data distribution. For normal distribution, parametric tests were performed and that did not follow normality, nonnormal tests were used, all with a significance level of 5% (p<0.05). Instrumentation with rotary files resulted in less time-consuming (p <0.001) than manual k-file. The percentage of non-instrument areas were similar for all systems. Accumulated debris was higher for K-file and XPS along the entire canal. All groups showed an increase in root canal volume after instrumentation (p= 0.003) with higher values in K-file (p <0.05). 3D analysis revealed greater transportation in K-file. SBF and K-file showed, respectively, the lowest (0.01± 0.01 and 0.03 ± 0.04) and highest (0.04 ± 0.05 and 0.32 ± 0.94) canal transportation value in the prototypes. Given the methodology applied, it was concluded that: the didactic material will be available on the digital platforms of Pediatric Dentistry at UFRJ for free access and widespread. From the overall mechanical instrumentation outcomes, the SBF and XPC resulted in a more conservative approach. Mechanical instrumentation may lead transportation and leave preparation. (AU)


Assuntos
Pulpectomia/instrumentação , Dente Decíduo , Fenômenos Biomecânicos , Odontólogos , Endodontia/instrumentação , Fatores de Tempo , Técnicas In Vitro , Guias de Prática Clínica como Assunto , Microtomografia por Raio-X , Dente Molar
8.
Braz. dent. sci ; 25(4): 1-15, 2022. tab, ilus, graf
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1400807

RESUMO

Objective: The purpose of this systematic review with bibliometric analysis was to map the available scientific evidence on intentional foraminal enlargement (IFE) and explore publication trends. Methods: This review is in accordance with the PRISMA 2020 Statement and is registered on the Open Science Framework. Two independent reviewers carried out a comprehensive search of seven databases (PubMed/MEDLINE, Cochrane Library, Scopus, Embase, Web of Science, LILACS, and BBO) up to January 31 st, 2022. Studies that investigated IFE were considered eligible, and the data were analyzed using the VOSViewer software. Results:The search identified a total of 55 IFE-related articles from 10 countries and 25 journals, with an increasing trend for publications over the last decade. The majority of evidence was based on laboratory assays (65.4%), followed by randomized clinical trials (18.1%) with follow-up periods of up to 2 months. The main clinical outcome evaluated was post-operative pain. The highest number of studies were carried out by the State University of Campinas, and published in the Journal of Endodontics. Also, studies with the highest level of evidence found that IFE resulted in greater post-operative pain in the initial days post-treatment. Conclusion:This systematic review with bibliometric analysis mapped the scientific progress and publication trends in the field of IFE, thus shedding light on gaps in the literature with the aim of guiding researchers to conduct more high-impact investigations by performing clinical studies evaluating rates of periapical repair and IFE treatment success using long-term observation periods (AU)


Objetivo: O objetivo desta revisão sistemática com análise bibliométrica foi mapear as evidências científicas disponíveis sobre ampliação foraminal intencional (IFE) e explorar as tendências de publicação. Métodos: Esta revisão está de acordo com a declaração PRISMA 2020 e está registrada no Open Science Framework. Dois revisores independentes realizaram uma busca abrangente em sete bases de dados (PubMed/MEDLINE, Cochrane Library, Scopus, Embase, Web of Science, LILACS e BBO) até 31 de janeiro de 2022. Os estudos que investigaram IFE foram considerados elegíveis e os dados foram analisados usando o software VOSViewer. Resultados: A busca identificou um total de 55 artigos relacionados ao IFE provenientes de 10 países e 25 periódicos, com tendência crescente de publicações na última década. A maioria das evidências foi baseada em ensaios laboratoriais (65,4%), seguido de ensaios clínicos randomizados (18,1%) com períodos de follow-up de até 2 meses. O principal desfecho clínico avaliado foi a dor pós-operatória. O maior número de estudos foi realizado pela Universidade Estadual de Campinas e publicado no Journal of Endodontics. Estudos com os maiores níveis de evidência constataram que IFE resultou em maior dor pós-operatória nos primeiros dias pós- tratamento. Conclusão: Esta revisão sistemática com análise bibliométrica mapeou o progresso científico e as tendências de publicação na área de IFE, lançando luz sobre lacunas na literatura com o objetivo de orientar pesquisadores a realizar investigações de maior impacto, realizando estudos clínicos avaliando taxas de reparo periapical e sucesso do tratamento usando essa técnica e com acompanhamento à longo prazo. (AU)


Assuntos
Bibliometria , Preparo de Canal Radicular , Endodontia , Revisão Sistemática
10.
Radiol. bras ; 54(6): 353-359, Nov.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422504

RESUMO

Abstract Objective: To present our clinical experience with percutaneous antegrade ureteral stenting. Materials and Methods This was a single-center retrospective study in which we reviewed the electronic medical records of patients who underwent percutaneous image-guided antegrade ureteral stenting between January 2016 and August 2020. We evaluated 90 patients (48 men). The mean age was 61.4 ± 15 years (range, 30-94 years). Patients were divided into two main groups: those with malignant neoplasms; and those with non-neoplastic disease. Technical and clinical success of the procedure were defined, respectively, as maintenance of the patency of the urinary tract, with a reduction in the degree of hydronephrosis, and as a reduction in the level of nitrogenous waste. Postprocedural complications were categorized as major or minor according to the CIRSE classification. Results: The study sample comprised 150 antegrade stenting procedures performed in 90 patients, most of whom had previously undergone retrograde stenting that was unsuccessful. The stenting was bilateral in 60 patients and unilateral in 30. Technical success was achieved in 143 (95.3%) of the procedures, whereas seven procedures (4.6%) were unsuccessful. Failed procedures were characterized by inability to place a stent or migration of a stent after its placement. Complications occurred in 12 (8.0%) of the procedures. Of those 12 complications, two were classified as major (bleeding) and 10 were classified as minor (lumbar pain or infection). The most common techniques used were the over-the-wire technique and the modified technique (in 58.0% and 42.0% of the cases, respectively). In seven cases (4.7%), a nephrostomy tube was inserted. Conclusion: Percutaneous antegrade ureteral stenting is a safe, effective method for the management of ureteral injuries and obstructions, due to malignant or benign causes, when the retrograde approach has failed.


Resumo Objetivo: Apresentar os resultados clínicos de 150 casos de inserção anterógrada de cateter duplo J. Materiais e Métodos: Foram revisados os prontuários eletrônicos de pacientes submetidos a inserção percutânea de cateter duplo J guiada por imagem entre janeiro de 2016 e agosto de 2020. Um total de 90 pacientes (48 homens e 42 mulheres; faixa etária, 30-94 anos; idade média, 61,4 ± 15 anos) foi incluído no estudo. Os pacientes foram classificados em dois grupos principais: neoplasia maligna e doença não neoplásica. O sucesso técnico e clínico do procedimento foi definido como a manutenção da perviedade da via urinária com redução do grau de hidronefrose e redução dos níveis das escórias nitrogenadas. As complicações pós-procedimento foram classificadas em maiores e menores, de acordo com o sistema de classificação CIRSE. Resultados: Foram realizados 150 procedimentos (90 pacientes) no período, sendo bilateral em 60 pacientes e unilateral em 30. Houve sucesso técnico em 143 casos (95,3%) e falhas em sete (4,7%), caracterizadas por migração e não progressão do cateter. Nossas taxas de complicações foram de 8,0% (12 casos), sendo dois maiores (sangramento) e 10 menores (principalmente dor lombar). As técnicas mais utilizadas para a inserção foram over the wire (58,0%) e modificada (42,0%). Em sete pacientes (4,7%) foi realizada nefrostomia percutânea. Conclusão: A inserção anterógrada do cateter duplo J é um método seguro e eficaz para o tratamento de obstruções uretéricas devidas a causas e lesões malignas e benignas, quando há uma falha na abordagem cistoscópica (retrógrada).

11.
Rev. Ciênc. Méd. Biol. (Impr.) ; 20(3): 431-435, dez 20, 2021. tab
Artigo em Português | LILACS | ID: biblio-1354283

RESUMO

Introdução: o tratamento endodôntico representa a terapia que trata as doenças pulpares e periapicais. O sucesso desse tratamento pode estar relacionado com o preparo do terço cervical e médio e a sua realização ou não contempla uma das vertentes da Endodontia contemporânea. Objetivo: identificar a prevalência de endodontistas que realizam o preparo cervical e médio, assim como as principais repercussões dentárias causadas por essa etapa, relacionando-as com instrumentos elencados neste estudo. Metodologia: trata ­ se de uma pesquisa observacional transversal que avalia, através de formulário online, a prevalência de endodontistas que realizam o pré-alargamento cervical e médio. O formulário foi enviado entre os dias 1º e 30 de junho de 2021, pela plataforma Google Forms. A amostra foi composta por 102 endodontistas de ambos os gêneros. O formulário apresenta questões de gênero, idade e questionamento sobre tempo de formação e trabalho. Resultados: verificou-se que 93,1% dos entrevistados alegaram realizar o preparo cervical e médio e a maioria, 67 respondentes, não acreditam que ele tem relação com o enfraquecimento dental. Para tal procedimento, a instrumentação rotatória é a mais utilzada com 54,9%. Conclusão: o preparo cervical e médio é uma etapa operatória presente na maioria dos tratamentos endodônticos e sua realização pode estar relacionada com o enfraquecimento dental, no entanto, isso não promove o insucesso do tratamento e, de acordo com os entrevistados, os instrumentos rotatórios são os mais utilizados para essa etapa.


Introduction: Endodontic treatment represents therapy that treats pulp and periapical diseases. The success of this treatment may be related to the preparation of the cervical and middle thirds and its realization or not contemplates one of the aspects of contemporary Endodontics. Objective: identify the prevalence of endodontists who perform cervical and middle preparation, as well as the main dental repercussions caused by this stage, relating them to the instruments listed in this study. Methodology: this is a cross-sectional observational study that assesses, through an online form, the prevalence of endodontists who perform cervical and mid-swelling pre-enlargement. The form was sent between June 1st and June 30th, 2021, by the Google Forms platform. The sample consisted of 102 endodontists of both genders. The form presents issues of gender, age and questions about training and work time. Results: it was found that 93.1% of respondents claimed to perform cervical and middle preparation and the majority, 67 respondents, do not believe that it is related to dental weakening. For this procedure, rotary instrumentation is the most used with 54.9%.Conclusion: cervical and middle preparation is an operative step present in most endodontic treatments and its performance ay be related to dental weakening, however, this does not promote treatment failure and, according to respondents, rotary instruments are the most used for this step.


Assuntos
Humanos , Masculino , Feminino , Doenças Periapicais , Cavidade Pulpar , Endodontia , Estudos Transversais , Estudo Observacional
12.
Arq. bras. oftalmol ; 84(6): 531-537, Nov.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1350079

RESUMO

ABSTRACT Purpose: To compare the quality of retinal images captured with a smartphone-based, handheld fundus camera with that of retinal images captured with a commercial fundus camera and to analyze their agreement in determining the cup-to-disc ratio for a cohort of ophthalmological patients. Methods: A total of 50 patients from a secondary ophthalmic outpatient service center underwent a bilateral fundus examination under mydriasis with a smartphone-based, handheld fundus camera and with a commercial fundus camera (4 images/patient by each). Two experienced ophthalmologists evaluated all the fundus images and graded them on the Likert 1-5 scale for quality. Multivariate regression analyses was then performed to evaluate the factors associated with the image quality. Two masked ophthalmologists determined the vertical cup-to-disc ratio of each fundus image, and both the intraobserver (between devices) and interobserver agreement between them was calculated. Results: Ninety-eight images from 49 patients were processed in this study for their quality analysis. Ten images from five patients (four from commercial fundus camera and one from smartphone-based, handheld fundus camera) were not included in the analyses due to their extremely poor quality. The medians [interquartile interval] of the image quality were not significantly different between those from the smartphone-based, handheld fundus camera and from the commercial fundus camera (4 [4-5] versus 4 [3-4] respectively, p=0.06); however, both the images captured with the commercial fundus camera and the presence of media opacity presented a significant negative correlation with the image quality. Both the intraobserver [intraclass correlation coefficient (ICC)=0.82, p<0.001 and 0.83, p<0.001, for examiners 1 and 2, respectively] and interobserver (ICC=0.70, p=0.001 and 0.81; p<0.001, for smartphone-based handheld fundus camera and commercial fundus camera, respectively) agreements were excellent and statistically significant. Conclusions: Our results thus indicate that the smartphone-based, handheld fundus camera yields an image quality similar to that from a commercial fundus camera, with significant agreement in the cup-to-disc ratios between them. In addition to the good outcomes recorded, the smartphone-based, handheld fundus camera offers the advantages of portability and low-cost to serve as an alternative for fundus documentation for future telemedicine approaches in medical interventions.


RESUMO Objetivo: Comparar a qualidade das imagens da retina capturadas com um retinógrafo portátil acoplado a um smartphone com aquelas adquiridas com um retinógrafo comercial padrão e analisar a concordância na determinação da relação escavação/ cabeça do nervo óptico em um coorte de pacientes de um serviço oftalmológico. Métodos: Cinquenta pacientes de um serviço oftalmológico secundário foram submetidos a uma avaliação do fundo de olho bilateral, sob midríase, utilizando o retinógrafo portátil acoplado a um smartphone e o retinógrafo comercial padrão (4 imagens por paciente). Dois oftalmologistas experientes avaliaram a qualidade de todas as imagens e atribuíram a elas uma pontuação entre 1 e 5, de acordo com a escala Likert. Os fatores relacionados a qualidade das imagens foram avaliados utilizando uma análise de regressão multivariada. Dois oftalmologistas determinaram de forma mascarada a relação da escavação/ cabeça do nervo óptico de cada imagem e a concordância intra e interobservador foi calculada. Resultados: Noventa e oito imagens de 49 pacientes foram utilizadas neste estudo para análise de qualidade. Dez imagens de cinco pacientes (quatro do retinógrafo comercial padrão e um do retinógrafo portátil acoplado a um smartphone) foram excluídas das análises de concordância devido à baixa qualidade das mesmas, mas foram considerados nas análises de qualidade. Dos cinco pacientes com imagens excluídas, quatro foram capturadas pelo retinógrafo comercial padrão e uma pelo retinógrafo portátil acoplado a um smartphone. As medianas (intervalo interquartil) da qualidade das imagens não apresentaram diferença estatística entre o retinógrafo portátil acoplado a um smartphone e o retinógrafo comercial padrão (4 [4-5] versus 4 [3-4] respectivamente, p=0.06). As imagens obtidas com o retinógrafo comercial padrão e o diagnóstico de opacidade de meios apresentou uma correlação negativa com a qualidade da imagem. As concordâncias intraobservador (ICC=0,82, p<0,001 e 0,83, p<0,001, para o examinador 1 e 2, respectivamente) e interobservador (ICC = 0,70, p=0,001 e 0,81, p<0.001, para o retinógrafo portátil acoplado a um smartphone e retinógrafo comercial padrão, respectivamente) foram excelentes e estatisticamente significativas. Conclusões: Nossos resultados sugerem que o retinógrafo portátil acoplado a um smartphone apresenta uma qualidade de imagem semelhante ao retinógrafo comercial padrão, com concordância significativa na análise da relação escavação-cabeça do nervo óptico. Além dos bons resultados apresentados, o retinógrafo portátil acoplado a um smartphone pode ser considerado uma alternativa portátil de baixo custo para documentação de retina em cenários futuros de telemedicina.

13.
Dent. press endod ; 11(1): 78-83, Jan-Apr2021.
Artigo em Inglês | LILACS | ID: biblio-1348257

RESUMO

Introdução: A infecção endodôntica pode alcançar a saída foraminal e, inclusive, ir além dela. Logo, a determinação da constrição apical como o limite ideal para instrumentação e obturação tem sido questionada. A instrumentação foraminal intencional é realizada com o intuito de diminuir o contingente microbiano a níveis mais favoráveis ao reparo. Entretanto, repercussões locais e sistêmicas estão associadas à sua execução. Objetivo: Realizar uma revisão crítica da literatura sobre repercussões locais e sistêmicas relativas à instrumentação foraminal intencional. Métodos: Em março de 2018, uma busca eletrônica realizada na base de dados PUBMED utilizando os termos "foraminal enlargement" OR "foraminal widening" OR "apical limit" AND "endodontics" identificou 74 artigos científicos. Esses artigos, a análise de suas referências bibliográficas e a utilização de mais 5 artigos base resultaram nos 111 estudos consultados para a realização dessa pesquisa. Resultados: A ampliação foraminal intencional nem sempre pode ser praticada em virtude de razões anatômicas e morfológicas. Quanto maior a ampliação do forame apical, maior a possibilidade de extravasamento de substâncias e/ou materiais utilizados para a realização do tratamento endodôntico. A instrumentação foraminal intencional parece ser contraindicada em pacientes que fazem ou fizeram uso de bisfosfonatos recentemente, com distúrbios de coagulação e/ou sob uso crônico de anticoagulantes e com alto risco de bacteremia. Conclusões: Os impactos da instrumentação foraminal intencional sobre o sucesso do tratamento endodôntico devem ser investigados. Contudo, os delineamentos metodológicos dos estudos clínicos devem ser cuidadosos, principalmente no tocante às condições sistêmicas dos pacientes que farão parte do universo amostral (AU).


Introduction: endodontic infection can reach and even go beyond the apical foramen. Therefore, determining apical constriction as the ideal limit for instrumentation and obturation has been questioned. Intentional foraminal enlargement is performed for the purpose of reducing the microbial contingent to levels more favorable to repair. However, local and systemic repercussions have been associated with this approach. Objectives: to critically review the literature on local and systemic repercussions relative to intentional foraminal enlargement. Methods: in March 2018, an electronic search performed on the PUBMED database using the terms "foraminal enlargement" OR "foraminal widening" OR "apical limit" AND "endodontics" identified 74 scientific articles. These articles, analysis of their references and use of another 5 base articles resulted in the 115 studies used for performing this research. Results: intentional foraminal enlargement cannot always be performed due to the anatomical and morphological conditions. The greater the apical foramen enlargement, the greater the possibility of extrusion of substances and/or materials used to perform endodontic treatment. Intentional foraminal enlargement seems to be contraindicated in patients who are taking or have recently used bisphosphonates, those with coagulation disorders and/ or under chronic use of anticoagulants and at high risk for bacteremia. Conclusions: the impacts of intentional foraminal enlargement on the success of endodontic treatment should be investigated. However, the methodological procedures of clinical studies should be carefully designed, especially taking into consideration the systemic conditions of patients who will be part of the sample (AU).


Assuntos
Ápice Dentário , Endodontia/instrumentação , Anticoagulantes , Difosfonatos , Infecções
14.
Arq. gastroenterol ; 57(4): 399-403, Oct.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1142343

RESUMO

ABSTRACT BACKGROUND: Covert hepatic encephalopathy (CHE) is difficult to detect due to the lack of easily applicable screening tools. The Stroop EncephalApp is a smartphone application already validated for CHE screening. However, its applicability to the Brazilian population is not known. OBJECTIVE: To estimate the prevalence of CHE and evaluate the use of Stroop EncephalApp in a cirrhotic population in Brazil. METHODS: In this cross-sectional study, we evaluated 99 patients previously diagnosed with liver cirrhosis in a Private Hospital in Curitiba/PR. Patients were initially submitted to the mini mental state examination (MMSE) to exclude individuals with dementia. After, the Psychometric Hepatic Encephalopathy Score (PHES) test was performed and lastly, the Stroop EncephalApp test. Results were adjusted for age, sex and education levels to evaluate the accuracy of the app on detecting the disease, comparing its results with the gold standard method (PHES). Patients with one or more of the following were excluded: dementia, inadequate MMSE score, illiteracy, color blindness, history of drugs/alcohol abuse within the past 3 months and previous or actual episodes of encephalopathy. The statistical analysis was performed by SPSS 2.0 and the significance adopted by 5%. RESULTS: We included 82 individuals in the final analysis. Among these patients, 29 were diagnosed with CHE by the PHES test (35.36% prevalence) and 28 of those obtained equal diagnosis by the Stroop EncephalApp (96.6% sensitivity). A total of 53 patients obtained negative results for CHE by PHES, while the Stroop test classified 27 of them as having the disease. In the multivariate analysis, high levels of education were associated with better performance during the tests. No significant relationship was observed between age and sex with the probability of diagnosing CHE through the PHES test.


RESUMO CONTEXTO: A encefalopatia hepática mínima (EHM) é uma complicação neuro-psiquiátrica da cirrose cuja detecção é dificultada pela falta de ferramentas práticas. O Stroop EncephalApp é um aplicativo de smartphones capaz de detectar a doença, entretanto sua aplicabilidade na população brasileira ainda não é conhecida. OBJETIVO: Avaliar o uso do Stroop EncephalApp para diagnóstico e avaliação de EHM em uma população de pacientes cirróticos no Brasil. MÉTODOS: Através de um estudo observacional transversal, 99 indivíduos sabidamente cirróticos foram recrutados do ambulatório de hepatologia de um hospital privado em Curitiba/PR. Primeiramente, foram aplicados o mini exame do estado mental (MEEM) para excluir indivíduos com demência; após, foram aplicados o Escore Psicométrico da Encefalopatia Hepática (PHES), atual padrão-ouro para diagnóstico de EHM, e posteriormente o Stroop EncephalApp, ajustando para idade, sexo e anos de formação acadêmica, buscando avaliar a eficiência do aplicativo em detectar a doença e comparar seus resultados com o atual padrão-ouro. Foram excluídos do estudo indivíduos com demência, pontuação insuficiente no MEEM, analfabetos, daltônicos, e com histórico de abuso de álcool/drogas ilícitas nos últimos 3 meses e paciente com episódios prévios ou atuais de encefalopatia hepática. A análise estatística foi realizada pelo SPSS 2.0 e a significância adotada em 5%. RESULTADOS: Um total de 82 indivíduos foram incluídos na análise final. Destes, 29 foram diagnosticados com EHM (35,36% de prevalência) através do PHES e 28 obtiveram o mesmo resultado após a aplicação do Stroop (96,6% de sensibilidade). Cinquenta e três pacientes obtiveram um resultado negativo para EHM através do PHES, sendo que 27 desses obtiveram um resultado positivo para EHM através do Stroop. Na análise multivariada, níveis elevados de escolaridade estiveram associados com melhor desempenho durante a execução dos testes. Não houve associação significativa entre idade e sexo com a probabilidade de apresentar encefalopatia através do PHES. CONCLUSÃO: O Stroop EncephalApp é uma ferramenta viável e com boa sensibilidade para o screening de EHM, mas possui baixa especificidade na população estudada.


Assuntos
Humanos , Encefalopatia Hepática , Encefalopatia Hepática/diagnóstico , Encefalopatia Hepática/epidemiologia , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico , Psicometria , Brasil/epidemiologia , Estudos Transversais
15.
Rev. Assoc. Med. Bras. (1992) ; 66(11): 1498-1502, Nov. 2020. graf
Artigo em Inglês | Sec. Est. Saúde SP, LILACS | ID: biblio-1143638

RESUMO

SUMMARY Additive Manufacturing (AM), also known as Rapid Prototyping, is a set of production technologies used in the synthesis of a particular physical object by adding layers to form a part based on data generated by Computer-Aided Design (CAD) systems. These technologies are widely used to quickly create prototypes of products and tools for commercial purposes. Over time, it has also been integrated with other areas, such as healthcare, since these tools have allowed health professionals to assist in diagnoses, surgical planning, and synthesis of orthoses and prostheses for patient rehabilitation. OBJECTIVE: To develop models for the construction of dilators for the treatment of vaginal agenesis. METHODS: Use CAD software and create a physical model using AM to analyze the viability of its production in the elaboration of customized dilators for each patient. RESULTS: The production through AM provides an advantage in the development, facilitating physical alterations just by adjusting the three-dimensional models made by the software in a quick way, thus making the customization process viable. CONCLUSION: The proposed procedure for the manufacture of dilators presented good results and technological feasibility, indicating that it can be a good solution for the production and customization of gynecological devices.


RESUMO A Manufatura Aditiva (MA), também conhecida como Prototipagem Rápida, é um conjunto de tecnologias de produção utilizado na síntese de determinado objeto físico por meio da adição de camadas para formar uma peça com base em dados gerados por sistemas de projeto auxiliado por computador (CAD - Computer Aided Design). Essas tecnologias são muito utilizadas para criação de protótipos de produtos e ferramentas de maneira rápida para fins comerciais. Com o tempo, também se integrou a outras áreas, como a área da saúde, uma vez que essas ferramentas permitiram auxiliar o profissional da saúde em diagnósticos, planejamento cirúrgico e na síntese de órteses e próteses para reabilitação de pacientes. OBJETIVO: Elaborar modelos computadorizados para a construção de dilatadores para tratamento de agenesia vaginal pela impressão 3D. MÉTODO: Utilização de software CAD e criação do modelo físico por meio de MA para análise da viabilidade de sua produção na elaboração de dilatadores customizados para cada paciente. RESULTADOS: A produção por meio de MA atribui uma vantagem ao desenvolvimento, facilitando as alterações físicas apenas ajustando os modelos tridimensionais feitos pelos softwares de maneira rápida, tornando o processo de customização viável. CONCLUSÃO: O procedimento proposto para a fabricação dos dilatadores apresentou bons resultados e viabilidade tecnológica, indicando que pode ser uma boa solução de produção e customização de dispositivos ginecológicos.


Assuntos
Humanos , Próteses e Implantes , Impressão Tridimensional , Vagina , Desenho Assistido por Computador
16.
Rev. bras. ter. intensiva ; 32(2): 235-243, Apr.-June 2020. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1138497

RESUMO

RESUMO Objetivo: Identificar as unidades de terapia intensiva neonatais, pediátricas e mistas (neonatais e pediátricas) no Brasil que utilizam cânulas traqueais com balonete na prática clínica, e descrever as características relacionadas à utilização de protocolos e monitoração. Métodos: Para identificação das unidades de terapia intensiva no Brasil, foi acessado o Cadastro Nacional de Estabelecimentos de Saúde do Ministério da Saúde, e foram obtidas informações de 693 unidades de terapia intensiva cadastradas. Trata-se de estudo transversal analítico do tipo survey realizado por questionário eletrônico enviado para 298 unidades de terapia intensiva neonatais, pediátricas e mistas do Brasil. Resultados: Este estudo analisou 146 questionários (49,3% de unidades de terapia intensiva neonatais, 35,6% de unidades de terapia intensiva pediátricas e 15,1% de unidades de terapia intensiva pediátricas mistas). A maioria das unidades participantes (78/146) utilizou cânulas traqueais com balonete, com predomínio de uso nas unidades de terapia intensiva pediátricas (52/78). A maioria das unidades que utilizou cânulas traqueais com balonete aplicou protocolo de monitoração da pressão do balonete (45/78). O uso de protocolos de monitoração do balonete foi observado nas unidades de terapia intensiva com Serviço de Fisioterapia exclusivo da unidade (38/61) e naquelas com tempo de atuação do fisioterapeuta 24 horas/dia (25/45). A causa de falha de extubação mais frequentemente relacionada ao uso de cânulas traqueais com balonete em unidades de terapia intensiva pediátricas foi a obstrução de vias aéreas superiores. Conclusão: Nesta enquete, houve predomínio do uso de cânulas traqueais com balonete e da aplicação de protocolo de monitoração da pressão do balonete em unidades de terapia intensiva pediátricas. A utilização de protocolo de monitoração foi mais frequente em unidades de terapia intensiva com fisioterapeuta exclusivo e com tempo de atuação 24 horas/dia.


ABSTRACT Objective: To identify the neonatal, pediatric and mixed (neonatal and pediatric) intensive care units in Brazil that use cuffed tracheal tubes in clinical practice and to describe the characteristics related to the use of protocols and monitoring. Methods: To identify the intensive care units in Brazil, the Ministry of Health's National Registry of Health Facilities was accessed, and information was collected on 693 registered intensive care units. This was an analytical cross-sectional survey conducted through electronic questionnaires sent to 298 neonatal, pediatric and mixed intensive care units in Brazil. Results: This study analyzed 146 questionnaires (49.3% from neonatal intensive care units, 35.6% from pediatric intensive care units and 15.1% from mixed pediatric intensive care units). Most of the participating units (78/146) used cuffed tracheal tubes, with a predominance of use in pediatric intensive care units (52/78). Most of the units that used cuffed tracheal tubes applied a cuff pressure monitoring protocol (45/78). The use of cuff monitoring protocols was observed in intensive care units with a physical therapy service exclusive to the unit (38/61) and in those with a physical therapist present 24 hours/day (25/45). The most frequent cause of extubation failure related to the use of cuffed tracheal tubes in pediatric intensive care units was upper airway obstruction. Conclusion: In this survey, the use of cuffed tracheal tubes and the application of a cuff pressure monitoring protocol was predominant in pediatric intensive care units. The use of a monitoring protocol was more common in intensive care units that had a physical therapist who was exclusive to the unit and was present 24 hours/day.


Assuntos
Humanos , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Unidades de Terapia Intensiva Pediátrica , Unidades de Terapia Intensiva Neonatal , Extubação/estatística & dados numéricos , Intubação Intratraqueal/instrumentação , Brasil , Estudos Transversais , Inquéritos e Questionários , Desenho de Equipamento , Fisioterapeutas/estatística & dados numéricos
17.
Rev. bras. med. esporte ; 26(2): 143-146, Mar.-Apr. 2020. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1092635

RESUMO

ABSTRACT Introduction: The numerous instruments used to measure jump height use different technologies and calculations that can provide variable results. Objective: This study compared the countermovement jump (CMJ) height assessed with a wearable 3D inertial measurement unit (IMU), using flight time and the numerical integration method with a force platform and photocells. Methods: Forty CMJs were analysed, starting from an upright standing position with the hands placed on the waist. Twenty healthy volunteers completed 2 CMJs, which were simultaneously assessed using an IMU placed on the subject's sacrum, a force platform (considered the gold standard method) and photocells. The maximum height of each CMJ was measured. Results: The results showed a significant overestimation (p<0.001) in jump height for the IMU using the numerical integration method when compared to the force platform (+7 cm). Excellent intraclass correlation coefficients (ICCs) were obtained with the flight time equations for the different types of measurement equipment. Fair to good ICCs were obtained with the IMU using the numerical integration method and force platform. Conclusion: In conclusion, the jump height obtained with the IMU using the numerical integration method showed the poorest agreement compared to the force platform. Level of evidence III; Prospective comparative study.


RESUMO Introdução: Os numerosos instrumentos usados para medir a altura de salto empregam diferentes tecnologias e cálculos que podem fornecer resultados variáveis. Objetivo: Este estudo comparou a altura de salto contramovimento (SCM) com uma unidade de medida inercial 3D (UMI) portátil, usando o tempo de voo e o método de integração numérica, com plataforma de força e fotocélulas. Métodos: Quarenta SCMs foram analisados a partir da posição ortostática com as mãos na cintura. Vinte voluntários saudáveis concluíram 2 SCMs que foram avaliados simultaneamente com uma UMI colocada no sacro do indivíduo, uma plataforma de força (considerado o método de referência) e fotocélulas. A altura máxima de cada SCM foi medida. Resultados: Os resultados mostraram uma superestimação significativa (p < 0,001) da altura do salto para a UMI com o método de integração numérica, em comparação com a plataforma de força (+7 cm). Foram obtidos excelentes coeficientes de correlação intraclasse (ICCs) com as equações de tempo de voo entre os equipamentos de medição. Foram obtidos resultados de regulares a bons de ICC com a UMI pelo método de integração numérica e a plataforma de força. Conclusão: A altura de salto obtida com a UMI com o método de integração numérica mostrou a pior concordância em comparação com a plataforma de força. Nível de evidência III; Estudo prospectivo comparativo.


RESUMEN Introducción: Los numerosos instrumentos usados para medir la altura del salto emplean diferentes tecnologías y cálculos que pueden suministrar resultados variables. Objetivo: Este estudio comparó la altura del salto contramovimiento (SCM) con una un sistema inercial 3D (IMU) portátil, usando el tiempo de vuelo y el método de integración numérica, con plataforma de fuerza y fotocélulas. Métodos: Cuarenta SCMs fueron analizados a partir de la posición ortostática con las manos en la cintura. Veinte voluntarios saludables concluyeron dos SCMs que fueron evaluados simultáneamente con un IMU colocada en el sacro del individuo, una plataforma de fuerza (considerado el método de referencia) y fotocélulas. Fue medida la altura máxima de cada SCM. Resultados: Los resultados mostraron una sobreestimación significativa (p <0,001) de la altura del salto para la IMU con el método de integración numérica, en comparación con la plataforma de fuerza (+7 cm). Fueron obtenidos excelentes coeficientes de correlación intraclase (ICCs) con las ecuaciones de tiempo de vuelo entre los equipamientos de medición. Fueron obtenidos resultados de regulares a buenos de ICC con la IMU por el método de integración numérica y la plataforma de fuerza. Conclusión: La altura de salto obtenida con la IMU con el método de integración numérica mostró la peor concordancia en comparación con la plataforma de fuerza. Nivel de evidencia III; Estudio prospectivo comparativo.

18.
São José dos campos; s.n; 2020. 60 p. il., graf., tab..
Tese em Português | BBO - Odontologia | ID: biblio-1248181

RESUMO

O objetivo deste estudo foi avaliar a capacidade de remoção de dentina radicular utilizando diferentes angulações de corte de um instrumento com sistema reciprocante, em um determinado período de tempo. Quarenta e cinco raízes uniradiculares de dentes humanos foram selecionadas através de tomografia computadorizada e padronizados com preparo prévio, através de um instrumento manual (tipo k) #15. Os espécimes foram divididos em 3 grupos (n=15) para instrumentação com o sistema Genius, previamente alterada a angulação com o auxílio de um transferidor: Grupo 1 Genius (G1) - Sistema Genius 25.04 em 16 mm com ângulos de corte e relaxamento (90º/30º), preconizados pelo fabricante, por 30 segundos; Grupo 2 Genius (G2) - Sistema Genius 25.04 em 16 mm com ângulos de corte e relaxamento (120º/60) por 30 segundos; Grupo 3 Genius (G3) - os espécimes foram instrumentados com sistema Genius 25.04 em 16 mm com ângulos de corte e relaxamento (70º/10º) por 30 segundos. Os resultados foram avaliados através da pesagem dos espécimes e pela volumetria através da tomografia computadorizada ambas realizadas pré e pós-instrumentação, e em relação aos ângulos de corte e recuo, todos os grupos apresentaram alteração no preparo biomecânico, quando comparado as suas respectivas rotações programadas no motor endodôntico Genius (Ultradent,2005). Os dados obtidos foram submetidos a análise de variância (ANOVA) e ao teste de Kruskal Wallis, onde o mesmo não apresentou diferença estatística significante entre os grupos. Dessa forma pode-se observar que todos os ângulos de corte e recuo, apresentaram alterações, não mantendo um preparo individualizado para cada dente, de acordo com suas complexidades em relação a morfologia radicular(AU)


The aim of this study was to evaluate the ability to remove root dentin using different cutting angles of an instrument with a reciprocating system, in a given period of time. Forty-five uni-root roots of human teeth were selected using computed tomography and standardized with prior preparation, using a manual instrument (type k) # 15. The specimens were divided into 3 groups (n = 15) for instrumentation with the Genius system, previously changed the angle with the aid of a protractor: Group 1 Genius (G1) - Genius 25.04 system in 16 mm with cutting and relaxation angles ( 90º / 30º), recommended by the manufacturer, for 30 seconds; Genius Group 2 (G2) - Genius 25.04 system in 16 mm with cutting and relaxation angles (120º / 60) for 30 seconds; Group 3 Genius (G3) - the specimens were instrumented with the Genius 25.04 system in 16 mm with cutting and relaxation angles (70º / 10º) for 30 seconds. The results were evaluated by weighing the specimens and by volumetry using computed tomography, both performed pre- and post-instrumentation, and in relation to the cutting and receding angles, all groups showed changes in the biomechanical preparation, when compared to their respective programmed rotations. in the Genius endodontic engine (Ultradent, 2005). The data obtained were subjected to analysis of variance (ANOVA) and the Kruskal Wallis test, where it did not show a statistically significant difference between the groups. In this way, it can be observed that all the cut and setback angles showed alterations, not maintaining an individualized preparation for each tooth, according to their complexities in relation to root morphology(AU)


Assuntos
Implantação Dentária Endo-Óssea Endodôntica/efeitos adversos , Implantação Dentária Endo-Óssea Endodôntica
19.
Rio de Janeiro; s.n; 2020. 61 p. ilus, tab.
Tese em Português | BBO - Odontologia | ID: biblio-1147966

RESUMO

O objetivo deste trabalho foi avaliar o resultado do preparo biomecânico da instrumentação endodôntica em protótipos de dentes decíduos intactos com sistemas mecanizados através de microtomografia computadorizada. Foram utilizados 50 protótipos de um incisivo central superior decíduo produzido através de impressão 3D. Os sistemas de limas empregados foram o manual (MN), WaveOne Gold (WOG), XP Endo Shaper (XPS), XP Endo Finisher (XPF) e XP Clean (XPC). Cada grupo contou com 10 dentes e foram instrumentados de acordo com as recomendações dos fabricantes. O escaneamento dos protótipos pelo micro-CT foi realizado antes e após a instrumentação e as reconstruções foram padronizadas para cada conjunto de imagens. O teste de Shapiro-Wilk foi utilizado para verificar a normalidade dos dados. O ANOVA seguido do teste de Tukey foi utilizado para comparar as médias de volume final do canal, formação de debris, volume de dentina removida e área não instrumentada das paredes do canal. O teste T de Student foi usado para comparar os volumes inicial e final do canal entre cada grupo de instrumentação. A presença de trincas e/ou perfurações ao longo do canal foi registrada e realizada uma descrição qualitativa da sua presença. Todos os grupos apresentaram uma diferença significativa no volume do canal após a instrumentação. O maior aumento de volume do canal foi com as limas manuais, que teve uma diferença estatística significativa quando comparado com os rotatórios, que não apresentaram diferença entre si. Em relação ao acumulo de debris e aréas não tocadas não houve diferença estatística entre os grupos. O maior volume de dentina removido foi quando utilizado as limas manuais. Apenas os grupos manual e WOG apresentaram trincas. Perfuração radicular foi observado apenas no grupo manual. Concluimos que o uso de sistemas rotatórios apresentou melhores resultados no preparo biomecânico do canal de incisivos superiores decíduos quando comparado à limas manuais. O sistema XP Clean combinou bons resultados, com pouco acumulo de debris e maior área tocada pelo instrumento no interior do canal. (AU)


The aim of this study was to evaluate the result of biomechanical preparation of endodontic instrumentation in prototypes of intact primary teeth with mechanized systems using computerized microtomography. 50 prototypes of a primary maxillary central incisor produced using 3D printing were used. The file systems used were hand files, WaveOne Gold (WOG), XP-Endo Shaper (XPS), XP-Endo Finisher (XPF) and XP Clean (XPC). Each group had 10 teeth and were instrumented according to the manufacturers' recommendations. The scanning of the prototypes by micro-CT was performed before and after instrumentation and the reconstructions were standardized for each set of images. The Shapiro-Wilk test was used to verify the normality of the data. ANOVA followed by the Tukey test was used to compare the averages of final canal volume, debris formation, dentin volume removed and untouched area of the canal walls. Student's t-test was used to compare the initial and final volumes of the canal between each instrumentation group. The presence of cracks and / or perforations along the canal was recorded and a qualitative description was made. All groups showed a significant difference in volume of the canal after instrumentation. The greatest increase in volume of the canal was with hand files, which had a statistically significant difference when compared to rotary files, which showed no difference among them. Regarding the accumulation of debris and noninstrumented areas, there was no statistical difference between the groups. The largest volume of dentin removed was when using hand files. Only the hand files and WOG groups showed cracks. Root perforation was observed only in the hand file group. We concluded that the use of rotary systems showed better results in the biomechanical preparation of the canal of primary maxillary incisors when compared to hand files. The XP Clean system combined good results, with little debris accumulation and a larger area played by the instrument inside the canal. (AU)


Assuntos
Dente Decíduo , Preparo de Canal Radicular/instrumentação , Instrumentos Odontológicos/normas , Microtomografia por Raio-X , Incisivo , Fenômenos Biomecânicos , Preparo de Canal Radicular/métodos
20.
Rev. saúde pública (Online) ; 54: 119, 2020. tab
Artigo em Inglês | Sec. Est. Saúde SP, BBO - Odontologia, LILACS | ID: biblio-1139465

RESUMO

ABSTRACT OBJECTIVE: To compare the Edmonton Frail Scale (EFS) and Clinical-Functional Vulnerability Index-20 (CFVI-20) instruments regarding degree of agreement and correlation and compare descriptive models with frailty-associated variables in community-dwelling older people in Brazil. METHODS: Cross-sectional study, nested in a population-based and household cohort. Baseline sampling was calculated based on a probabilistic approach by conglomerate in two stages. In the first stage, census tract was used as sampling unit. In the second, the number of households was defined according to the population density of individuals aged ≥ 60 years. The Kappa statistic evaluated the agreement between instruments and Pearson's coefficient their correlation. Factors associated with frailty and high risk of clinical-functional vulnerability were identified by multiple analysis of Poisson regression with robust variance. RESULTS: Kappa statistics was 0.599 and Pearson's correlation coefficient 0.755 (p < 0.001). The EFS found a 28.2% prevalence of frailty, and the CFVI-20 found a 19.5% prevalence of high risk of clinical-functional vulnerability. Age equal to or greater than 80 years, history of stroke, polypharmacy, negative self-perceived health, fall in the past 12 months, and hospitalization in the past 12 months were variables associated with frailty in both instruments after multiple analysis. Less than four years of education, osteoarticular disease, and weight loss were associated with frailty only by EFS, and having a caregiver was associated with a high risk of clinical-functional vulnerability only by CFVI-20. CONCLUSIONS: Although the analyses show moderate agreement and strong positive correlation between the instruments, the indicated prevalence of frailty is discrepant. Our results attest the need to standardize the instrument for assessing frailty in community-dwelling older people.


RESUMO OBJETIVO: Comparar os instrumentos Edmonton Frail Scale (EFS) e Índice de Vulnerabilidade Clínico-Funcional-20 (IVCF-20) quanto ao grau de concordância e de correlação, bem como comparar modelos descritivos com variáveis associadas à fragilidade em idosos brasileiros comunitários. MÉTODOS: Estudo transversal, aninhado a uma coorte de base populacional e domiciliar. A amostragem na linha de base foi probabilística, por conglomerados, em dois estágios. No primeiro, utilizou-se como unidade amostral o setor censitário. No segundo, definiu-se o número de domicílios segundo a densidade populacional de indivíduos com idade ≥ a 60 anos. A estatística Kappa analisou a concordância, e o coeficiente de Pearson avaliou a correlação entre os instrumentos. Os fatores associados à fragilidade e ao alto risco de vulnerabilidade clínico-funcional foram identificados por análise múltipla de regressão de Poisson com variância robusta. RESULTADOS: A estatística Kappa foi 0,599, e o coeficiente de correlação de Pearson foi de 0,755 (p < 0,001). A prevalência da fragilidade foi de 28,2% pela EFS, e a prevalência do alto risco de vulnerabilidade clínico-funcional foi de 19,5% pelo IVCF-20. As variáveis associadas à fragilidade, após análise múltipla, em ambos os instrumentos, foram: idade igual ou superior a 80 anos, histórico de acidente vascular encefálico, polifarmácia, autopercepção negativa de saúde, queda nos últimos 12 meses e internação nos últimos 12 meses. Escolaridade inferior a quatro anos, doença osteoarticular e perda de peso foram associadas a fragilidade apenas pela EFS, enquanto possuir cuidador esteve associado a alto risco de vulnerabilidade clínico-funcional somente pelo IVCF-20. CONCLUSÕES: Embora as análises revelem concordância moderada e forte correlação positiva entre os instrumentos, a prevalência de fragilidade apontada é discrepante. O resultado destaca a necessidade de padronizar o instrumento para aferir a fragilidade em idosos comunitários.


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Programas de Rastreamento/instrumentação , Idoso Fragilizado , Vida Independente , Fragilidade/diagnóstico , Fragilidade/epidemiologia , Brasil/epidemiologia , Prevalência , Estudos Transversais , Reprodutibilidade dos Testes , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...